{"id":6696,"date":"2026-11-06T11:56:24","date_gmt":"2026-11-06T11:56:24","guid":{"rendered":"https:\/\/plugplaykit.com\/?post_type=docs&#038;p=6696"},"modified":"2026-11-06T11:56:26","modified_gmt":"2026-11-06T11:56:26","password":"","slug":"mp28-pressure-sensor","status":"publish","type":"docs","link":"https:\/\/plugplaykit.com\/es\/docs\/mp28-pressure-sensor\/","title":{"rendered":"Choosing a PPK-MP28 Pressure Sensor: Output, Supply, and Range"},"content":{"rendered":"<article lang=\"en-US\">\n<header>A pressure sensor can have the right thread and still be the wrong part for your controller. With the PPK-MP28, start with the electrical interface, then choose the pressure range. Those two decisions define the version you need.<\/p>\n<\/header>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall.png\" alt=\"PPK-MP28 pressure sensor with threaded body, cable, and connector on a white background\" width=\"1254\" height=\"1254\" \/><figcaption>The PPK-MP28 combines a compact threaded body with a cable connection. Connector appearance alone does not identify the electrical version.<\/figcaption><\/figure>\n<h2>One product family, seven electrical versions<\/h2>\n<p>The PPK-MP28 is offered with voltage, current, and digital outputs. These are separate purchase configurations. A sensor ordered with a voltage output does not become an RS485 sensor through a software setting.<\/p>\n<p>Before choosing a letter code, check the input on the device that will receive the measurement. An analog voltage input, a current input, and a serial interface require different electrical connections. The sensor&#8217;s supply voltage is a separate requirement from its output signal.<\/p>\n<table>\n<caption>PPK-MP28 electrical version selection<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Version<\/th>\n<th scope=\"col\">Supply<\/th>\n<th scope=\"col\">Output<\/th>\n<th scope=\"col\">What to match<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">A<\/th>\n<td>3.3 V<\/td>\n<td>0.5\u20132.5 V<\/td>\n<td>An analog input that accepts the full 0.5\u20132.5 V signal.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">B<\/th>\n<td>5 V<\/td>\n<td>0.5\u20134.5 V<\/td>\n<td>An analog input that accepts the full 0.5\u20134.5 V signal.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">C<\/th>\n<td>3.3 V<\/td>\n<td>I\u00b2C<\/td>\n<td>An I\u00b2C interface, with the device address and data format established before integration.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">D<\/th>\n<td>12\u201324 V<\/td>\n<td>0\u201310 V<\/td>\n<td>A voltage input designed for a 0\u201310 V measurement signal.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">E<\/th>\n<td>12\u201324 V<\/td>\n<td>4\u201320 mA<\/td>\n<td>A compatible current input and the correct connection arrangement.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">F<\/th>\n<td>12\u201324 V<\/td>\n<td>RS485<\/td>\n<td>An RS485 interface and the correct communication protocol.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">G<\/th>\n<td>3.3\u20135 V<\/td>\n<td>UART<\/td>\n<td>A compatible UART interface, including signal levels and serial settings.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For example, a controller powered from 3.3 V is not automatically compatible with version B: B needs a 5 V supply and can output 4.5 V. Likewise, a 24 V control system does not tell you whether to order D, E, or F. That choice depends on whether its receiving input is 0\u201310 V, 4\u201320 mA, or RS485.<\/p>\n<p>For the digital versions, the interface name is only the starting point. RS485 does not by itself mean Modbus. I\u00b2C and UART also need device-specific communication information. Establish the protocol, register or message format, and relevant settings before planning the software.<\/p>\n<h2>Choose both ends of the pressure range<\/h2>\n<p>The second selector is the measurement range. There are ten options: five beginning at zero and five beginning at \u2212100 kPa. Read the lower limit as carefully as the upper limit, particularly when the measurement needs to include negative pressure.<\/p>\n<table>\n<caption>The ten available pressure ranges<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Upper limit<\/th>\n<th scope=\"col\">Zero-based option<\/th>\n<th scope=\"col\">Negative-pressure option<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">100 kPa<\/th>\n<td>0 to 100 kPa<\/td>\n<td>\u2212100 to 100 kPa<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">1 MPa<\/th>\n<td>0 to 1 MPa<\/td>\n<td>\u2212100 kPa to 1 MPa<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">1.6 MPa<\/th>\n<td>0 to 1.6 MPa<\/td>\n<td>\u2212100 kPa to 1.6 MPa<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">3 MPa<\/th>\n<td>0 to 3 MPa<\/td>\n<td>\u2212100 kPa to 3 MPa<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">3.5 MPa<\/th>\n<td>0 to 3.5 MPa<\/td>\n<td>\u2212100 kPa to 3.5 MPa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The mixed units matter. \u201c\u2212100 kPa to 1 MPa\u201d has a lower limit of \u22120.1 MPa, not \u2212100 MPa. Choosing the same upper limit does not make the zero-based and negative-pressure versions interchangeable.<\/p>\n<p>Consider a measurement that needs to cover \u221250 kPa to +80 kPa. The \u2212100 to +100 kPa option includes both ends; the 0 to 100 kPa option does not. This is a range-selection example, not an approval for a particular fluid or installation.<\/p>\n<h2>What \u00b10.5%FS tells you<\/h2>\n<p>The specified accuracy is \u00b10.5%FS. FS means full scale; it is not a promise of \u00b10.5% of every reading. Choose a range that covers the expected measurement conditions rather than automatically picking the highest upper limit.<\/p>\n<p>The operating temperature is \u221240 to 125\u00b0C. Keep the temperature rating separate from the pressure range and the electrical supply: meeting one requirement does not establish that the complete installation meets all three.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/04-dimensions.png\" alt=\"PPK-MP28 dimension illustration showing a 37 mm body dimension, 20 mm width, and G1\/4 thread\" width=\"1254\" height=\"1254\" \/><figcaption>The dimension illustration marks 37 mm and 20 mm on the body and identifies the G1\/4 threaded connection. It is not a dimensioned drawing of the complete cable assembly.<\/figcaption><\/figure>\n<h2>Check the mechanical fit before the wiring<\/h2>\n<p>The threaded process connection is G1\/4. Match it to the mating fitting and the required sealing arrangement; do not choose a fitting by visual similarity alone. The illustrated body dimensions help with space planning, but leave room for the cable and connector as well.<\/p>\n<p>The medium in contact with the sensor also matters. Establish material and seal compatibility for the actual fluid or gas before installation. A threaded metal body, by itself, does not establish suitability for corrosive media, food contact, or hazardous locations.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-acg.png\" alt=\"Close-up of the PPK-MP28 sensor body, hex section, and threaded pressure connection\" width=\"1254\" height=\"1254\" \/><figcaption>Use the connection specification to select a mating fitting. The photo does not define a wiring pinout or certify media compatibility.<\/figcaption><\/figure>\n<h2>Before connecting your selected version<\/h2>\n<ul>\n<li><strong>Check the exact supply.<\/strong> Do not apply 12\u201324 V to a 3.3 V or 5 V version.<\/li>\n<li><strong>Check the receiving input.<\/strong> It must accept the selected output signal or digital interface.<\/li>\n<li><strong>Use the correct pin assignments.<\/strong> Do not copy wire colors from a photograph of another version.<\/li>\n<li><strong>Check the pressure limits.<\/strong> Confirm both ends of the selected range and the system&#8217;s expected operating conditions.<\/li>\n<li><strong>Check the process connection and medium.<\/strong> Thread fit and material compatibility are separate checks.<\/li>\n<\/ul>\n<h2>How to place the right order<\/h2>\n<p>Write down the required supply, output, and pressure limits before opening the selectors. For an input accepting 0.5\u20132.5 V with a 3.3 V sensor supply, start with version A. If that measurement must include negative pressure up to a positive limit of 100 kPa, select \u2212100 to 100 kPa as the range. Other controller requirements lead to a different electrical version, even when the mechanical body looks similar.<\/p>\n<p><a href=\"https:\/\/plugplaykit.com\/es\/?post_type=product&amp;p=6623\">View the PPK-MP28 pressure sensor and choose an electrical version and pressure range.<\/a><\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>A pressure sensor can have the right thread and still be the wrong part for your controller. With the PPK-MP28, start with the electrical interface, then choose the pressure range. Those two decisions define the version you need. The PPK-MP28 combines a compact threaded body with a cable connection. Connector appearance alone does not identify [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":6621,"comment_status":"open","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_uag_custom_page_level_css":"","_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"doc_category":[53],"doc_tag":[],"class_list":["post-6696","docs","type-docs","status-publish","has-post-thumbnail","hentry","doc_category-product-blog"],"year_month":"2026-11","word_count":857,"total_views":"2","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"PlugPlayKit Team","author_nicename":"die7uj39gmail-com","author_url":"https:\/\/plugplaykit.com\/es\/author\/die7uj39gmail-com\/"},"doc_category_info":[{"term_name":"Product Blog","term_url":"https:\/\/plugplaykit.com\/es\/docs-category\/product-blog\/"}],"doc_tag_info":[],"uagb_featured_image_src":{"full":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall.png?v=1793957806",1254,1254,false],"thumbnail":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall-150x150.png?v=1793957806",150,150,true],"medium":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall-300x300.png?v=1793957806",300,300,true],"medium_large":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall-768x768.png?v=1793957806",768,768,true],"large":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall-1024x1024.png?v=1793957806",1024,1024,true],"1536x1536":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall.png?v=1793957806",1254,1254,false],"2048x2048":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall.png?v=1793957806",1254,1254,false],"trp-custom-language-flag":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall-12x12.png?v=1793957806",12,12,true],"mailpoet_newsletter_max":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall.png?v=1793957806",1254,1254,false],"woocommerce_thumbnail":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall-300x300.png?v=1793957806",300,300,true],"woocommerce_single":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall-600x600.png?v=1793957806",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall-100x100.png?v=1793957806",100,100,true],"variation_swatches_image_size":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall-50x50.png?v=1793957806",50,50,true],"variation_swatches_tooltip_size":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/03-overall-100x100.png?v=1793957806",100,100,true]},"uagb_author_info":{"display_name":"PlugPlayKit Team","author_link":"https:\/\/plugplaykit.com\/es\/author\/die7uj39gmail-com\/"},"uagb_comment_info":0,"uagb_excerpt":"A pressure sensor can have the right thread and still be the wrong part for your controller. With the PPK-MP28, start with the electrical interface, then choose the pressure range. Those two decisions define the version you need. The PPK-MP28 combines a compact threaded body with a cable connection. Connector appearance alone does not identify&hellip;","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/docs\/6696","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/comments?post=6696"}],"version-history":[{"count":2,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/docs\/6696\/revisions"}],"predecessor-version":[{"id":6698,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/docs\/6696\/revisions\/6698"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/media\/6621"}],"wp:attachment":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/media?parent=6696"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/doc_category?post=6696"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/doc_tag?post=6696"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}