{"id":6704,"date":"2026-11-06T13:05:22","date_gmt":"2026-11-06T13:05:22","guid":{"rendered":"https:\/\/plugplaykit.com\/?post_type=product&#038;p=6704"},"modified":"2026-11-06T13:55:38","modified_gmt":"2026-11-06T13:55:38","slug":"qy20-pressure-sensor","status":"publish","type":"product","link":"https:\/\/plugplaykit.com\/es\/producto\/qy20-pressure-sensor\/","title":{"rendered":"Compact Air Pressure Sensor Module"},"content":{"rendered":"<p>The PPK-QY20 is a small MEMS pressure sensor module for air-pressure measurement in controller-based designs. Its circular PCB measures 15 mm across, with a pressure port on the sensor side and a cable connection on the reverse.<\/p>\n<p>Choose the electrical version and pressure range separately. A and B provide specified voltage-output ranges; H provides an output proportional to its supply voltage. Each combination is a separate purchase configuration, not a software-selectable mode.<\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>15 mm circular PCB for compact integration.<\/li>\n<li>MEMS sensing technology for air-pressure measurement.<\/li>\n<li>Three analog voltage configurations: A, B and H.<\/li>\n<li>Seven selectable electrical-version and pressure-range combinations.<\/li>\n<li>Positive-only and negative-to-positive range options, depending on version.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Model<\/th>\n<td>PPK-QY20<\/td>\n<\/tr>\n<tr>\n<th>Sensing technology<\/th>\n<td>MEMS<\/td>\n<\/tr>\n<tr>\n<th>Measured medium<\/th>\n<td>Air \/ gas; verify the intended gas compatibility before installation<\/td>\n<\/tr>\n<tr>\n<th>PCB diameter<\/th>\n<td>15 mm<\/td>\n<\/tr>\n<tr>\n<th>Supply voltage<\/th>\n<td>A 3.3 V; B 5 V; H 3.3\u20135 V<\/td>\n<\/tr>\n<tr>\n<th>Voltage output<\/th>\n<td>A 0.5\u20132.5 V; B 0.5\u20134.5 V; H 10\u201390% of supply voltage<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature for voltage-output type<\/th>\n<td>\u221240 to 84\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Comprehensive accuracy for voltage-output type<\/th>\n<td>0.5\u20131%, including zero and temperature drift<\/td>\n<\/tr>\n<tr>\n<th>Available combinations<\/th>\n<td>Seven; see model selection guide<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Model Selection Guide<\/h2>\n<ul>\n<li>| Version | Supply | Output | Available ranges | How to choose |<\/li>\n<li>| A | 3.3 V | 0.5\u20132.5 V | \u2212100 to +100 kPa; 0 to 100 kPa | Match an analog input that accepts the full 0.5\u20132.5 V signal. |<\/li>\n<li>| B | 5 V | 0.5\u20134.5 V | \u221210 to +10 kPa; \u2212100 to +100 kPa; \u2212100 to +1000 kPa | Match an analog input that accepts the full 0.5\u20134.5 V signal. |<\/li>\n<li>| H | 3.3\u20135 V | 10\u201390% of supply voltage | \u221210 to +10 kPa; \u2212100 to +100 kPa | Choose for a controller designed to measure an output proportional to the sensor supply. |<\/li>\n<li>For H, the stated output range corresponds to 0.33\u20132.97 V at a 3.3 V supply, or 0.5\u20134.5 V at 5 V. These values are the stated supply percentages expressed in volts, not a separate calibration or accuracy specification.<\/li>\n<li>For a measurement that crosses zero, select a range with a negative lower limit. The A version&#8217;s 0 to 100 kPa option does not cover negative pressure. A \u221210 to +10 kPa version and a \u2212100 to +100 kPa version have different spans even when their electrical output format is the same.<\/li>\n<\/ul>\n<h2>Applications<\/h2>\n<ul>\n<li>Air-pressure monitoring integrated with a controller that accepts the selected analog output and supply requirements.<\/li>\n<li>Positive and negative pressure measurement designs, using the appropriate selected range.<\/li>\n<\/ul>\n<h2>Wiring \/ Installation<\/h2>\n<ul>\n<li>The three-wire connection illustration identifies red as supply positive, black as supply negative, and yellow as signal output. Match the actual received module and selected supply voltage before connecting power.<\/li>\n<li>The cable illustration specifies a 19 cm lead and an XH connector labeled with a 2.54 mm pitch. Verify the mating connector dimensions before designing a fixed connector footprint.<\/li>\n<\/ul>\n<h2>Compatibility &amp; Important Notes<\/h2>\n<ul>\n<li>Do not apply the voltage of another version to the selected module. A 5 V supply is not the specified supply for A.<\/li>\n<li>The receiver must accept the entire selected output range. A controller&#8217;s supply voltage alone does not establish its analog input limits.<\/li>\n<li>The voltage-output accuracy figure includes zero and temperature drift; do not treat it as a guarantee of the same percentage of every reading. No independent calibration results are included.<\/li>\n<li>Use the selected measurement range as a limit for selection; do not treat an overload figure as an allowed continuous operating range.<\/li>\n<li>The exposed PCB needs an appropriate installation environment. Keep liquids away from the electronics and do not assume the module is waterproof or approved for direct liquid contact.<\/li>\n<li>Use this module for compatible gas-pressure measurement. This product page does not establish medical-device approval, food-contact certification, or compatibility with flammable or corrosive gases.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>A compact MEMS air pressure sensor module with a 15 mm circular PCB. Choose a 3.3 V or 5 V fixed-output version, or a supply-proportional output, then select the pressure range your controller needs.<\/p>","protected":false},"featured_media":6700,"comment_status":"open","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_uag_custom_page_level_css":"","_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[46,44],"product_tag":[],"class_list":["post-6704","product","type-product","status-publish","has-post-thumbnail","product_cat-air-pressure-sensors","product_cat-sensors","desktop-align-center","tablet-align-center","mobile-align-center","first","instock","taxable","shipping-taxable","purchasable","product-type-variable"],"uagb_featured_image_src":{"full":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front.png?v=1793970291",1254,1254,false],"thumbnail":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-150x150.png?v=1793970291",150,150,true],"medium":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-300x300.png?v=1793970291",300,300,true],"medium_large":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-768x768.png?v=1793970291",768,768,true],"large":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-1024x1024.png?v=1793970291",1024,1024,true],"1536x1536":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front.png?v=1793970291",1254,1254,false],"2048x2048":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front.png?v=1793970291",1254,1254,false],"trp-custom-language-flag":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-12x12.png?v=1793970291",12,12,true],"mailpoet_newsletter_max":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front.png?v=1793970291",1254,1254,false],"woocommerce_thumbnail":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-300x300.png?v=1793970291",300,300,true],"woocommerce_single":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-600x600.png?v=1793970291",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-100x100.png?v=1793970291",100,100,true],"variation_swatches_image_size":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-50x50.png?v=1793970291",50,50,true],"variation_swatches_tooltip_size":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-100x100.png?v=1793970291",100,100,true]},"uagb_author_info":{"display_name":"PlugPlayKit Team","author_link":"https:\/\/plugplaykit.com\/es\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"A compact MEMS air pressure sensor module with a 15 mm circular PCB. Choose a 3.3 V or 5 V fixed-output version, or a supply-proportional output, then select the pressure range your controller needs.","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/product\/6704","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/comments?post=6704"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/media\/6700"}],"wp:attachment":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/media?parent=6704"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/product_brand?post=6704"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/product_cat?post=6704"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/product_tag?post=6704"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}