{"id":6774,"date":"2026-11-11T16:17:28","date_gmt":"2026-11-11T16:17:28","guid":{"rendered":"https:\/\/plugplaykit.com\/?post_type=product&#038;p=6774"},"modified":"2026-11-11T16:27:50","modified_gmt":"2026-11-11T16:27:50","slug":"qy9-i2c-pressure-sensor","status":"publish","type":"product","link":"https:\/\/plugplaykit.com\/es\/producto\/qy9-i2c-pressure-sensor\/","title":{"rendered":"I2C Air Pressure Sensor \u2014 SOP6"},"content":{"rendered":"<p>The PPK-QY9 is a surface-mount pressure sensor for PCB-based gas-pressure measurement. A MEMS piezoresistive sensing element and signal-conditioning circuitry provide calibrated pressure and temperature data through I2C.<\/p>\n<p>Its SOP6 package has a pressure port and six solder leads. This is a bare sensor component for integration into your own circuit, rather than a ready-to-connect sensor board or wired transmitter.<\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Three pressure-range versions for positive-only or negative-to-positive measurements.<\/li>\n<li>1.8\u20133.6 V supply for low-voltage electronic designs.<\/li>\n<li>I2C standard and fast modes, up to 100 kHz and 400 kHz respectively.<\/li>\n<li>24-bit pressure data and 16-bit temperature data.<\/li>\n<li>Temperature-compensated output for dry, non-corrosive gases.<\/li>\n<li>Low-power measurement and standby operation, subject to the stated sampling conditions.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Model<\/th>\n<td>PPK-QY9<\/td>\n<\/tr>\n<tr>\n<th>Package<\/th>\n<td>SOP6, surface mount<\/td>\n<\/tr>\n<tr>\n<th>Sensing principle<\/th>\n<td>MEMS piezoresistive pressure sensing with signal conditioning<\/td>\n<\/tr>\n<tr>\n<th>Medium<\/th>\n<td>Dry, non-corrosive gases<\/td>\n<\/tr>\n<tr>\n<th>Supply voltage<\/th>\n<td>1.8\u20133.6 V<\/td>\n<\/tr>\n<tr>\n<th>Interface<\/th>\n<td>I2C, standard mode up to 100 kHz or fast mode up to 400 kHz<\/td>\n<\/tr>\n<tr>\n<th>Pressure data word<\/th>\n<td>24 bits<\/td>\n<\/tr>\n<tr>\n<th>Temperature data word<\/th>\n<td>16 bits<\/td>\n<\/tr>\n<tr>\n<th>Total error band<\/th>\n<td>\u00b11% of span at 0\u201360\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Working temperature<\/th>\n<td>\u221240 to +85\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Storage temperature<\/th>\n<td>\u221240 to +125\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Default I2C address<\/th>\n<td>0x78, 7-bit, if unchanged during calibration<\/td>\n<\/tr>\n<tr>\n<th>Operating current<\/th>\n<td>9.5 \u03bcA typical at 1 Hz with minimum pressure and temperature oversampling<\/td>\n<\/tr>\n<tr>\n<th>Standby current<\/th>\n<td>0.1 \u03bcA typical; 0.3 \u03bcA maximum<\/td>\n<\/tr>\n<tr>\n<th>Current specification conditions<\/th>\n<td>3.3 V supply and 25\u00b0C unless otherwise specified<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Model Selection Guide<\/h2>\n<ul>\n<li>| Version | Measurement range | How to choose |<\/li>\n<li>| Bipolar 100 kPa | \u2212100 to +100 kPa | Select when the measurement crosses zero and both negative and positive pressure must be covered. |<\/li>\n<li>| Positive 200 kPa | 0 to 200 kPa | Select for positive-pressure measurements within 200 kPa. This version does not cover negative pressure. |<\/li>\n<li>| Positive 1000 kPa | 0 to 1000 kPa | Select for positive-pressure measurements up to 1 MPa. This version does not cover negative pressure. |<\/li>\n<li>All three versions use the same supply range, SOP6 package and I2C interface. Select the calibrated pressure range your design requires; a wider range is not a claim of better accuracy or resolution.<\/li>\n<\/ul>\n<h2>Applications<\/h2>\n<ul>\n<li>PCB-based pressure instruments for dry, non-corrosive gases.<\/li>\n<li>Vacuum-pump and pneumatic-system monitoring using the appropriate pressure range.<\/li>\n<li>Embedded pressure measurement with a compatible I2C microcontroller.<\/li>\n<\/ul>\n<h2>Wiring \/ Installation<\/h2>\n<ul>\n<li>| Pin | Name | Function |<\/li>\n<li>| 1 | NC | No connection |<\/li>\n<li>| 2 | SDA | I2C data |<\/li>\n<li>| 3 | SCL | I2C clock |<\/li>\n<li>| 4 | VDD | Positive supply, 1.8\u20133.6 V |<\/li>\n<li>| 5 | NC | No connection |<\/li>\n<li>| 6 | VSS | Ground |<\/li>\n<li>Use the package pinout and footprint drawing to establish orientation before laying out or soldering the component. Do not infer pin numbering from a product photo.<\/li>\n<li>The application circuit uses 4.7 k\u03a9 pull-up resistors on SDA and SCL and a 0.1 \u03bcF supply bypass capacitor. Connect the bus to a compatible low-voltage host; do not apply a 5 V supply to the sensor.<\/li>\n<li>The default seven-bit address is 0x78 when it has not been changed during calibration. Do not enter the eight-bit write-address byte 0xF0 as a seven-bit device address.<\/li>\n<li>Start a calibrated measurement with command 0xAC. Wait until status bit 5 clears, then read the status byte, three pressure bytes and two temperature bytes. Convert the pressure count using the selected range and calibration endpoints. The I2C data is not a direct pressure value in kPa.<\/li>\n<\/ul>\n<h2>Compatibility &amp; Important Notes<\/h2>\n<ul>\n<li>Use only dry, non-corrosive gases. Keep liquids and condensation away from the sensing path.<\/li>\n<li>The 24-bit data word is a data format, not a promise of 24-bit effective accuracy. The \u00b11% span error band is specified at 0\u201360\u00b0C and must not be extended to the entire working-temperature range.<\/li>\n<li>Storage temperature is not the operating-temperature rating. Select the pressure range for normal operation rather than treating overpressure tolerance as an extra measurement range.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>A compact SOP6 pressure sensor for dry, non-corrosive gases, with I2C communication and a 1.8\u20133.6 V supply. Choose a \u2212100 to +100 kPa, 0\u2013200 kPa, or 0\u20131000 kPa version for your PCB-based pressure measurement design.<\/p>","protected":false},"featured_media":6770,"comment_status":"open","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_uag_custom_page_level_css":"","_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[46],"product_tag":[],"class_list":["post-6774","product","type-product","status-publish","has-post-thumbnail","product_cat-air-pressure-sensors","desktop-align-center","tablet-align-center","mobile-align-center","first","instock","taxable","shipping-taxable","purchasable","product-type-variable"],"uagb_featured_image_src":{"full":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2.png?v=1794413770",1254,1254,false],"thumbnail":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2-150x150.png?v=1794413770",150,150,true],"medium":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2-300x300.png?v=1794413770",300,300,true],"medium_large":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2-768x768.png?v=1794413770",768,768,true],"large":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2-1024x1024.png?v=1794413770",1024,1024,true],"1536x1536":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2.png?v=1794413770",1254,1254,false],"2048x2048":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2.png?v=1794413770",1254,1254,false],"trp-custom-language-flag":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2-12x12.png?v=1794413770",12,12,true],"mailpoet_newsletter_max":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2.png?v=1794413770",1254,1254,false],"woocommerce_thumbnail":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2-300x300.png?v=1794413770",300,300,true],"woocommerce_single":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2-600x600.png?v=1794413770",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2-100x100.png?v=1794413770",100,100,true],"variation_swatches_image_size":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2-50x50.png?v=1794413770",50,50,true],"variation_swatches_tooltip_size":["https:\/\/plugplaykit.com\/wp-content\/uploads\/2026\/11\/01-front-2-100x100.png?v=1794413770",100,100,true]},"uagb_author_info":{"display_name":"PlugPlayKit Team","author_link":"https:\/\/plugplaykit.com\/es\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"A compact SOP6 pressure sensor for dry, non-corrosive gases, with I2C communication and a 1.8\u20133.6 V supply. Choose a \u2212100 to +100 kPa, 0\u2013200 kPa, or 0\u20131000 kPa version for your PCB-based pressure measurement design.","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/product\/6774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/comments?post=6774"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/media\/6770"}],"wp:attachment":[{"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/media?parent=6774"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/product_brand?post=6774"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/product_cat?post=6774"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/plugplaykit.com\/es\/wp-json\/wp\/v2\/product_tag?post=6774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}