The PPK-LD010 is a 60GHz FMCW radar liquid level sensor with RS485 Modbus communication. It provides non-contact measurement up to 10m with high accuracy, strong anti-interference capability, and IP68 waterproof protection. Designed for industrial applications, it is ideal for water tanks, wastewater treatment, storage tanks, and automation systems.

Guaranteed Safe Checkout

PPK-LD010 Radar Liquid Level Sensor

RS485 FMCW Radar Level Sensor for Industrial Liquid Measurement

The LD010 radar liquid level sensor uses FMCW (Frequency Modulated Continuous Wave) radar technology to achieve accurate and stable non-contact liquid level measurement.

With a compact industrial design, IP68 waterproof protection, RS485 communication, and long-distance detection capability up to 10 meters, it is suitable for water resources, wastewater treatment, storage tanks, chemical processing, and industrial automation applications.


Key Features

1. Long-Distance Detection up to 10m

The LD010 radar level sensor supports a maximum detection distance of 10 meters.

With millimeter-level measurement capability and stable radar signal processing, it provides reliable liquid level monitoring even in challenging environments.


2. FMCW Radar Technology

Adopts FMCW continuous wave radar technology combined with advanced signal processing algorithms.

Advantages:

  • Strong anti-interference capability
  • Stable measurement in turbulent environments
  • Reliable performance under changing conditions

Suitable for applications where traditional contact sensors are difficult to install.


3. High Accuracy & Strong Anti-Interference Performance

The sensor integrates advanced filtering technology to effectively suppress interference signals.

Features:

  • High measurement stability
  • Excellent electromagnetic interference resistance
  • No influence from water vapor, dust, or environmental changes

Supports the 60–64GHz ISM frequency band and complies with FCC and CE standards.


4. Industrial-Grade Waterproof Design

Designed for harsh outdoor and industrial environments.

Features:

  • IP68 waterproof protection
  • Flame-retardant PP housing material
  • Aerospace-grade waterproof connector
  • Easy installation with mounting bracket

Suitable for long-term outdoor operation.


Applications

The LD010 radar liquid level sensor is widely used in:

Water Reservoirs

Real-time monitoring of water level in reservoirs and water management systems.

Wastewater Treatment Plants

Suitable for sewage tanks and wastewater monitoring.

Liquid Storage Tanks

Used for industrial liquid storage and process control.

Aquaculture Tanks

Supports water level monitoring in farming and breeding systems.

Underground Drainage Systems

Suitable for drainage wells and flood monitoring applications.

Chemical Processing Tanks

Used for liquid level detection in chemical and industrial environments.


Product Specifications

Parameter Specification
Model XKC-LD010-RS485
Output Interface RS485
Communication Protocol RS485
Detection Range Up to 10m
Working Frequency 60–64GHz
Detection Angle 10°–13°
Response Time ≤500ms
Measurement Accuracy ±0.1%
Power Supply DC 9V–28V
Maximum Power Consumption <3W
Operating Temperature -40°C ~ +85°C
Protection Rating IP68
Communication Cable Length Main cable: 500mm / Extension cable: 2000mm (customizable)
Connector M12-4P Waterproof Aviation Connector
Housing Material Flame-retardant PP
Certification CE, RoHS 2.0

Cable Definition

Wire Color Function
Brown VCC (Power Supply)
Blue GND
Yellow RS485-B
Black RS485-A

Working Principle

The LD010 radar liquid level sensor works based on FMCW radar technology.

The sensor continuously transmits high-frequency radar waves toward the liquid surface. When the radar signal reaches the liquid surface, part of the signal is reflected back to the sensor.

By analyzing the frequency difference between transmitted and received signals, the sensor calculates the distance between the sensor and the liquid surface, allowing accurate liquid level measurement.

Because the radar signal does not require direct contact with the liquid, the sensor is unaffected by:

  • Corrosive liquids
  • Foam
  • Dust
  • Temperature changes
  • Water vapor

Measurement Method

The LD010 measurement blind zone is 0–15cm.

During measurement:

  • Data fluctuations may occur within approximately ±5cm around the target area.
  • Response time may vary between approximately 0.5s–2s depending on application conditions.

For optimal measurement accuracy:

  • The detected target should be within the effective detection range.
  • The signal path should remain unobstructed.

The effective detection distance depends on the detection angle and installation environment.


Package Contents

Standard package includes:

  • Radar level sensor ×1
  • Extension cable ×1
  • Mounting bracket ×1
  • Screws ×1 set
  • PE protection bag ×1
  • Packaging box ×1

Installation Notes

To ensure accurate and stable radar level measurement, please follow the installation guidelines below:

1. Ensure Clear Radar Signal Transmission

The radar antenna should be aligned directly toward the measurement area.

Keep the area around the antenna free from obstacles to avoid signal blockage or reflection interference.


2. Ensure Stable Installation

The sensor must be installed firmly and securely.

Any movement or vibration of the radar sensor may affect measurement accuracy and stability.


3. Avoid Moving Objects Behind the Sensor

The area behind the radar sensor should be free from moving objects or vibration sources.

Since radar waves have penetration characteristics, objects behind the sensor may generate reflected signals and affect measurement results.

For applications with unavoidable background interference, a metal shielding plate or metal backplane can be installed to reduce unwanted reflections.


4. Measurement Accuracy Considerations

Radar theoretical distance accuracy is based on physical resolution and advanced algorithm processing.

Due to factors such as:

  • Floating objects on the liquid surface
  • Wave fluctuations
  • Liquid turbulence

Actual measurement values may have slight variations.


RS485 Communication Protocol

1. Modbus Protocol Introduction

The LD010 radar level sensor supports the standard Modbus RTU communication protocol.

Supported Function Codes:

Function Code Description
03H Read Holding Registers
06H Write Single Register
10H Write Multiple Registers

Address Definition

  • Slave address: 1 byte
  • Broadcast address: 0
  • Slave address range: 1–247
  • Reserved address: 248–255

Communication Parameters

Default communication settings:

Parameter Value
Baud Rate 9600 bps
Data Bits 8 bits
Parity None
Stop Bits 1 bit

CRC Verification

CRC uses 2 bytes.

Little-endian mode.

Verification range:

Slave Address + Function Code + Data Area


Modbus Address Description

Modbus addresses are normally based on starting from 1, while many MCU systems use addresses starting from 0.

Therefore:

  • Some PLC systems may require address offset adjustment.
  • Some master devices automatically subtract 1.
  • Please confirm address settings during integration.

Communication Function Codes

Function Code Exception Code Description Operation
03H 83H Read Holding Registers Read single or multiple registers
06H 86H Write Single Register Write one register
10H 90H Write Multiple Registers Write multiple registers

Register Address Map

Register Address Function Data Range R/W
0001H Set Slave ID 0 = Broadcast, 1–247 = Slave Address R/W
0011H Read Distance Data Unit: mm R
0012H Calibration Command 0000 W
0013H Distance Upload Mode 0000 Auto Upload / 0001 Manual Upload R/W
0014H Buzzer Enable 0000 Disable / 0001 Enable R/W
0015H Baud Rate Setting 01–08 R/W
0016H Restore Default Settings Write 0001 Restore W
0017H System Status Bit Status Information R
0018H Calibration Reference Distance 0–10000 mm R/W
0019H Sensor Detection Distance 0–10000 mm R/W
001AH Empty Distance Unit: mm R/W
001BH Output Liquid Level Height Unit: mm R
001CH Liquid Level Calibration Value Unit: mm R/W
001DH Upgrade Flag Reserved R/W
001FH Calibration K Value 10000 Corresponds to 1 R/W
0020H Radar Reference Distance Offset Unit: mm R/W
0021H Current Distance Value Unit: mm R

Baud Rate Selection

Code Baud Rate
01 1200
02 2400
03 4800
04 9600
05 19200
06 38400
07 57600
08 115200

1 review for PPK-LD010 Radar Level Transmitter

Customer Images

Image #1 from David Miller
Image #1 from David Miller

David Miller

eal-time river level monitoring, all-weather accuracy even in heavy rain.

Image #1 from David Miller
5.0 Rating
1-1 of 1 review
  1. eal-time river level monitoring, all-weather accuracy even in heavy rain.

    Image #1 from David Miller
Add a review
PPK-LD010 Radar Level Transmitter PPK-LD010 Radar Level Transmitter
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
Add photos or video to your review
Shopping Cart
Radar Level TransmitterPPK-LD010 Radar Level Transmitter
Original price was: $79.00.Current price is: $59.90.