The PPK-QY20 is a small MEMS pressure sensor module for air-pressure measurement in controller-based designs. Its circular PCB measures 15 mm across, with a pressure port on the sensor side and a cable connection on the reverse.
Choose the electrical version and pressure range separately. A and B provide specified voltage-output ranges; H provides an output proportional to its supply voltage. Each combination is a separate purchase configuration, not a software-selectable mode.
Key Features
- 15 mm circular PCB for compact integration.
- MEMS sensing technology for air-pressure measurement.
- Three analog voltage configurations: A, B and H.
- Seven selectable electrical-version and pressure-range combinations.
- Positive-only and negative-to-positive range options, depending on version.
Technical Specifications
| Model | PPK-QY20 |
|---|---|
| Sensing technology | MEMS |
| Measured medium | Air / gas; verify the intended gas compatibility before installation |
| PCB diameter | 15 mm |
| Supply voltage | A 3.3 V; B 5 V; H 3.3–5 V |
| Voltage output | A 0.5–2.5 V; B 0.5–4.5 V; H 10–90% of supply voltage |
| Operating temperature for voltage-output type | −40 to 84°C |
| Comprehensive accuracy for voltage-output type | 0.5–1%, including zero and temperature drift |
| Available combinations | Seven; see model selection guide |
Model Selection Guide
- | Version | Supply | Output | Available ranges | How to choose |
- | A | 3.3 V | 0.5–2.5 V | −100 to +100 kPa; 0 to 100 kPa | Match an analog input that accepts the full 0.5–2.5 V signal. |
- | B | 5 V | 0.5–4.5 V | −10 to +10 kPa; −100 to +100 kPa; −100 to +1000 kPa | Match an analog input that accepts the full 0.5–4.5 V signal. |
- | H | 3.3–5 V | 10–90% of supply voltage | −10 to +10 kPa; −100 to +100 kPa | Choose for a controller designed to measure an output proportional to the sensor supply. |
- For H, the stated output range corresponds to 0.33–2.97 V at a 3.3 V supply, or 0.5–4.5 V at 5 V. These values are the stated supply percentages expressed in volts, not a separate calibration or accuracy specification.
- For a measurement that crosses zero, select a range with a negative lower limit. The A version’s 0 to 100 kPa option does not cover negative pressure. A −10 to +10 kPa version and a −100 to +100 kPa version have different spans even when their electrical output format is the same.
Applications
- Air-pressure monitoring integrated with a controller that accepts the selected analog output and supply requirements.
- Positive and negative pressure measurement designs, using the appropriate selected range.
Wiring / Installation
- The three-wire connection illustration identifies red as supply positive, black as supply negative, and yellow as signal output. Match the actual received module and selected supply voltage before connecting power.
- The cable illustration specifies a 19 cm lead and an XH connector labeled with a 2.54 mm pitch. Verify the mating connector dimensions before designing a fixed connector footprint.
Compatibility & Important Notes
- Do not apply the voltage of another version to the selected module. A 5 V supply is not the specified supply for A.
- The receiver must accept the entire selected output range. A controller’s supply voltage alone does not establish its analog input limits.
- The voltage-output accuracy figure includes zero and temperature drift; do not treat it as a guarantee of the same percentage of every reading. No independent calibration results are included.
- Use the selected measurement range as a limit for selection; do not treat an overload figure as an allowed continuous operating range.
- The exposed PCB needs an appropriate installation environment. Keep liquids away from the electronics and do not assume the module is waterproof or approved for direct liquid contact.
- Use this module for compatible gas-pressure measurement. This product page does not establish medical-device approval, food-contact certification, or compatibility with flammable or corrosive gases.