The PPK-QY19 measures gas pressure through a 6 mm pneumatic tube push-fit connection. Its 37 mm body and attached cable provide a compact format for integration into a pressure-monitoring assembly.
Choose the electrical version first, then the pressure range. These are separate hardware configurations: selecting a version does not give one sensor switchable outputs or all pressure ranges.
Key Features
- 6 mm pneumatic tube push-fit connection.
- 37 mm illustrated sensor-body length, excluding the cable.
- Fixed analog voltage and supply-proportional voltage output options.
- Positive-only and negative-to-positive pressure ranges, depending on version.
Technical Specifications
| Model | PPK-QY19 |
|---|---|
| Measured medium | Gas |
| Tube connection | 6 mm pneumatic tube push-fit |
| Illustrated body length | 37 mm, excluding cable |
| Supply and output | Version-specific; see selection table |
| Operating temperature | −40 to +125°C |
| Comprehensive accuracy, voltage-output type | 0.5–1% FS, including zero error, span error and temperature drift |
| Hysteresis / repeatability, voltage-output type | ≤0.1% FS |
| Temperature drift, voltage-output type | ±0.04% FS/°C |
| Long-term stability, voltage-output type | Better than 0.2% FS/year |
| Overload, voltage-output type | 1.5 × selected range; not a continuous operating rating |
| Reverse polarity protection, voltage-output type | Included |
Model Selection Guide
- | Version | Supply | Output | Available pressure ranges | Selection guidance |
- | A | 3.3 V | 0.5–2.5 V | −100 to +100; −100 to +1000; 0 to 100 kPa | Choose for an analog input that accepts the full 0.5–2.5 V signal. |
- | B | 5 V | 0.5–4.5 V | −10 to +10; −100 to +100; −100 to +1000 kPa | Choose for an analog input that accepts the full 0.5–4.5 V signal. |
- | H | 3.3–5 V | 10–90% of supply | −10 to +10; −100 to +100 kPa | Choose for a receiver designed to read a signal proportional to sensor supply voltage. |
- For measurements that cross zero, choose a range with a negative lower limit. The 0 to 100 kPa option covers positive pressure only. Select a range that contains your expected minimum and maximum pressure; the same voltage output can represent different pressure spans.
- For H, 10–90% corresponds to 0.33–2.97 V at a 3.3 V supply, or 0.5–4.5 V at 5 V. These are calculated endpoints, not additional calibration specifications.
Applications
- Gas-pressure measurement in a controller-based monitoring assembly with a compatible electrical input and selected pressure range.
- Positive and negative pressure monitoring, using a version whose selected range covers the measurement.
Wiring / Installation
- The voltage-output wiring illustration identifies red as supply positive, black as supply negative, and yellow as signal output. This three-wire illustration applies to the voltage-output type.
- Use the supply voltage specified for the selected version. The receiving input must accept the complete output range.
Compatibility & Important Notes
- The 6 mm specification identifies the pneumatic tube connection, not the sensor-body diameter.
- Use the selected pressure range as the operating selection limit. An overload rating does not extend the normal measurement range.