I2C Air Pressure Sensor — SOP6

$3.90

A compact SOP6 pressure sensor for dry, non-corrosive gases, with I2C communication and a 1.8–3.6 V supply. Choose a −100 to +100 kPa, 0–200 kPa, or 0–1000 kPa version for your PCB-based pressure measurement design.

Calculate shipping price

Please fill in the fields below with the shipping destination details in order to calculate the shipping cost.

Guaranteed Safe Checkout

The PPK-QY9 is a surface-mount pressure sensor for PCB-based gas-pressure measurement. A MEMS piezoresistive sensing element and signal-conditioning circuitry provide calibrated pressure and temperature data through I2C.

Its SOP6 package has a pressure port and six solder leads. This is a bare sensor component for integration into your own circuit, rather than a ready-to-connect sensor board or wired transmitter.

Key Features

  • Three pressure-range versions for positive-only or negative-to-positive measurements.
  • 1.8–3.6 V supply for low-voltage electronic designs.
  • I2C standard and fast modes, up to 100 kHz and 400 kHz respectively.
  • 24-bit pressure data and 16-bit temperature data.
  • Temperature-compensated output for dry, non-corrosive gases.
  • Low-power measurement and standby operation, subject to the stated sampling conditions.

Technical Specifications

Model PPK-QY9
Package SOP6, surface mount
Sensing principle MEMS piezoresistive pressure sensing with signal conditioning
Medium Dry, non-corrosive gases
Supply voltage 1.8–3.6 V
Interface I2C, standard mode up to 100 kHz or fast mode up to 400 kHz
Pressure data word 24 bits
Temperature data word 16 bits
Total error band ±1% of span at 0–60°C
Working temperature −40 to +85°C
Storage temperature −40 to +125°C
Default I2C address 0x78, 7-bit, if unchanged during calibration
Operating current 9.5 μA typical at 1 Hz with minimum pressure and temperature oversampling
Standby current 0.1 μA typical; 0.3 μA maximum
Current specification conditions 3.3 V supply and 25°C unless otherwise specified

Model Selection Guide

  • | Version | Measurement range | How to choose |
  • | Bipolar 100 kPa | −100 to +100 kPa | Select when the measurement crosses zero and both negative and positive pressure must be covered. |
  • | Positive 200 kPa | 0 to 200 kPa | Select for positive-pressure measurements within 200 kPa. This version does not cover negative pressure. |
  • | Positive 1000 kPa | 0 to 1000 kPa | Select for positive-pressure measurements up to 1 MPa. This version does not cover negative pressure. |
  • All three versions use the same supply range, SOP6 package and I2C interface. Select the calibrated pressure range your design requires; a wider range is not a claim of better accuracy or resolution.

Applications

  • PCB-based pressure instruments for dry, non-corrosive gases.
  • Vacuum-pump and pneumatic-system monitoring using the appropriate pressure range.
  • Embedded pressure measurement with a compatible I2C microcontroller.

Wiring / Installation

  • | Pin | Name | Function |
  • | 1 | NC | No connection |
  • | 2 | SDA | I2C data |
  • | 3 | SCL | I2C clock |
  • | 4 | VDD | Positive supply, 1.8–3.6 V |
  • | 5 | NC | No connection |
  • | 6 | VSS | Ground |
  • Use the package pinout and footprint drawing to establish orientation before laying out or soldering the component. Do not infer pin numbering from a product photo.
  • The application circuit uses 4.7 kΩ pull-up resistors on SDA and SCL and a 0.1 μF supply bypass capacitor. Connect the bus to a compatible low-voltage host; do not apply a 5 V supply to the sensor.
  • The default seven-bit address is 0x78 when it has not been changed during calibration. Do not enter the eight-bit write-address byte 0xF0 as a seven-bit device address.
  • Start a calibrated measurement with command 0xAC. Wait until status bit 5 clears, then read the status byte, three pressure bytes and two temperature bytes. Convert the pressure count using the selected range and calibration endpoints. The I2C data is not a direct pressure value in kPa.

Compatibility & Important Notes

  • Use only dry, non-corrosive gases. Keep liquids and condensation away from the sensing path.
  • The 24-bit data word is a data format, not a promise of 24-bit effective accuracy. The ±1% span error band is specified at 0–60°C and must not be extended to the entire working-temperature range.
  • Storage temperature is not the operating-temperature rating. Select the pressure range for normal operation rather than treating overpressure tolerance as an extra measurement range.
Configuration

−100 to +100 kPa, 0 to 200 kPa, 0 to 1000 kPa

Valoraciones

Aún no hay reseñas

Añadir una reseña
I2C Air Pressure Sensor — SOP6 I2C Air Pressure Sensor — SOP6