The DS1603 Series is an external, non-invasive ultrasonic liquid level sensor designed for continuous depth detection without drilling holes. Featuring built-in temperature compensation and flexible signal outputs (UART, RS485, Analog Voltage), it provides high-precision liquid tracking for smart tanks and automation systems.

Calculate shipping price

Please fill in the fields below with the shipping destination details in order to calculate the shipping cost.

Guaranteed Safe Checkout

Model Selection Guide

Please choose the corresponding output protocol model based on your controller or PLC requirements:

Model Specification Output Description
DS1603L UART Serial Port TTL-UART digital serial output for MCU/Arduino/Raspberry Pi integration.
DS1603-AQ Analog Output Proportional analog voltage output for analog signal collection.
DS1603NF Normally Open (NO) Relay output with Normally-Open contact for liquid level switch control.
DS1603NFK Normally Closed (NC) Relay output with Normally-Closed contact for safety/alarm logic circuits.
DS1603DA-RS485 RS485 Interface RS485 Modbus industrial communication for long-distance PLC/SCADA systems.
L023MPNW Low-Voltage Analog Output Low-voltage version operating at 2.8V – 5V power supply with analog output.

Non-Contact Ultrasonic Liquid Level Sensor Module (DS1603 Series)

The DS1603 Series Non-Contact Ultrasonic Liquid Level Sensor provides high-precision, non-invasive liquid depth detection without drilling holes or altering your container structure. Mounted directly to the bottom or outer wall of the vessel, it emits ultrasonic pulses through the container material to accurately measure real-time liquid levels.

Equipped with built-in temperature compensation, it automatically adjusts measurement values according to environmental changes, making it an ideal choice for smart home automation, water tank level monitoring, and industrial liquid management.

Key Features

  • Non-Invasive Measurement: Attaches externally to the tank bottom. Zero contact with liquid ensures anti-corrosion, clean, and leak-free operation.
  • Built-in Temperature Compensation: Ensures stable accuracy across varying temperature environments.
  • Real-Time Continuous Tracking: Supports dynamic tracking. No system restart is required when filling an empty tank.
  • Multiple Output Interfaces: Available in UART (DS1603L V1.0), RS485 (DS1603DA V1.0), and Analog Voltage (DS1603AQ V1.0) versions for flexible MCU and PLC integration.

⚠️ Critical Operating & Tank Compatibility Requirements

To ensure reliable ultrasound penetration and accurate measurements, please verify that your application meets all of the following conditions prior to installation:

  1. Container Material & Thickness: Must be an integrated/seamless metal container wall with a thickness between 0.5 mm and 5.0 mm.
  2. Surface Condition: The probe mounting area on the container wall must be free of paint, rust, coating, or heavy oxide layers (clean metal surface required).
  3. Container Size / Pipe Diameter:
    • For tanks/containers: Outer diameter must not exceed 2 meters.
    • For pipes: Outer diameter must be larger than 15 cm.
  4. Liquid Purity: The measured liquid should be clear with low impurity/sediment levels to prevent sound wave scattering.
  5. Internal Obstructions: The interior acoustic path must be unobstructed (hollow) and contain liquid only (no internal baffles, mixers, or bubbles).
  6. Operating Temperature: Maximum liquid/vessel temperature must not exceed 60°C (140°F).

Technical Specifications

Parameter DS1603L V1.0 DS1603DA V1.0 DS1603AQ V1.0
Operating Voltage DC 3.3V – 12V DC 10V – 36V DC 10V – 36V
Detection Range 5 cm – 200 cm 5 cm – 200 cm 5 cm – 100 cm
Output Signal UART Output RS485 Output Analog Voltage Output
Measurement Accuracy ±(5 + S * 0.5%) mm ±(5 + S * 1.0%) mm ±(10 + S * 1.0%) mm
Dimensions Probe Diameter: 27.7mm ± 0.5mm | Height: 17mm ± 1mm | Cable Length: 450mm ± 10mm

* Note: S represents the current detected liquid level height in millimeters.


Applications

  • Smart home appliance liquid monitoring (e.g., water dispensers, coffee machines)
  • Water tank & storage container level management
  • High-risk liquid level detection & automated pump control (High/Low limit control)
  • DIY electronics & industrial automation projects
Model

DS1603L(UART), DS1603‑AQ, DS1603NF, DS1603NFK, DS1603DA‑RS485, L023MPNW (2.8‑5V)

Reviews

There are no reviews yet

Add a review
Non-Contact Ultrasonic Liquid Level Sensor - External Tank Depth Sensor Module Non-Contact Ultrasonic Liquid Level Sensor - External Tank Depth Sensor Module
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
Add photos or video to your review
Shopping Cart
Ultrasonic Liquid Level SensorNon-Contact Ultrasonic Liquid Level Sensor – External Tank Depth Sensor Module
Original price was: $39.00.Current price is: $29.90.Select options